Hi,
    Thanks for your reply... and i just got the ManualRtNode running...
by using
$n1 add-route-to-adj-node -default $r1
..


Regards
Tan Su Wei

----- Original Message -----
From: Tarik Alj <[email protected]>
To: <[email protected]>
Cc: <[email protected]>
Sent: Thursday, January 20, 2000 8:40 PM
Subject: Re: Questions about ManualRtNode, hash classifier


> Tan,
>
> i think the probleme comes from:
>
> # manual set route
> $n1 add-route-to-adj-node $r1
> $r1 add-route-to-adj-node $r2
> $r2 add-route-to-adj-node $r5
> $r5 add-route-to-adj-node $r4
> $r4 add-route-to-adj-node $n2
>
> the unknown flow error comes from the classifier being unable to map the
flow
>  from 0 to 256 with fid of 0 (1 stands for the bucket number) to a slot.
Either
> you are not using these intsproc correctly or you've stepped across a bug?
>
> > X-Authentication-Warning: mash.CS.Berkeley.EDU: majrdomo set sender to
> [email protected] using -f
> > Date: Thu, 20 Jan 2000 16:21:28 +0000
> > From: Tan Su Wei <[email protected]>
> > X-Accept-Language: en
> > MIME-Version: 1.0
> > To: "[email protected]" <[email protected]>
> > Subject: Questions about ManualRtNode, hash classifier
> >
> > Dear all,
> >     I'd tried to simulate a manual route packet forwarding using
> > ManualRtNode {in ns-node.tcl}, I got some error when trying to run a
> > simple simulation script.
> > I can figure out what is wrong with the script and no sure what the
> > error message means. Can some one please show me how to used
> > ManualRtNode or the hashclassifier for setting up a pre comfigure path.
> >
> > Attach is my simulation script... and below is the error message
> > generated....
> >
> > <error: --------------------
> > ns: _o11 unknown-flow 0 256 0 1:
> >     (_o11 cmd line 1)
> >     invoked from within
> > "_o11 cmd unknown-flow 0 256 0 1"
> >     invoked from within
> > "catch "$self cmd $args" ret"
> >     (procedure "_o11" line 2)
> >     (SplitObject unknown line 2)
> >     invoked from within
> > "_o11 unknown-flow 0 256 0 1"
> > -------------------------->
> >
> > Regards
> > Tan Su Wei
> Tarik
>
>